UPAPAP8453 specification sheet

Current Specials & Promotions
Product specification information

Specifications for UPAPAP8453

Apc Rack PDU 2G, Metered-by-Outlet, ZeroU, 32A, 230V

UPAPAP8453 Gallery image 1 [Size: 197 (W) x 494 (H)]  
Apc Rack PDU 2G, Metered-by-Outlet, ZeroU, 32A, 230V, (21) C13 & (3) C19, 200, 208, 230, 230, 23.10(lbs) 10.48(kilos), 80.20x 6.40x 4.60(in) 203.70x 16.30x 11.70(cent)

Server cabinet / enclosure accessories

APC (American Power Convertion)

In Stock (not confirmed) Enquire now!
R 33 215.00 inc VAT

Overview:

APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection. Current metering provides real-time remote monitoring of connected loads. Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

Features:
 
Availability
Metering-by-Outlet capability 
Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.
 
Network Management Capabilities 
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
 
Alarm Thresholds 
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
 
Local Current Monitoring Display 
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
 
Load indicator LED 
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. (Note: Only available with units with local current monitoring feature)
 
Flash Upgradeable 
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
 
Integrates with StruxureWare Data Center Expert 
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
 
Agility
Single input power source 
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Specifications:

©2026 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered.
Specificationsspacer
Product CodeAP8453spacer
Output
Nominal Output Voltage 230V
Maximum Total Current Draw per Phase 32A
Output Connections (21) IEC 320 C13
(3) IEC 320 C19
Overload Protection Yes
Input
Nominal Input Voltage 200V, 208V, 230V
Input Frequency 50/60 Hz
Input Connections IEC 309 32A 2P+E
Cord Length 3 meters
Number of Power Cords 1
Acceptable Input Voltage 220-240 VAC
Maximum Line Current per phase 32A
Maximum Input Current per phase 32A
Physical
Net Weight 8.21 KG
Maximum Height 1829.00 mm
Maximum Width 56.00 mm
Maximum Depth 51.00 mm
Shipping Weight 10.48 KG
Shipping Height 2037.00 mm
Shipping Width 163.00 mm
Shipping Depth 117.00 mm
Color Black
Units per Pallet 48
Environmental
Operating Environment -5 - 45 °C
Operating Relative Humidity 5 - 95%
Operating Elevation 0-3000 meters
Storage Temperature -25 - 65 °C
Storage Relative Humidity 5 - 95%
Storage Elevation 0-15000 meters
Conformance
Regulatory Approvals EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE
Sustainable Offer Status
RoHS Compliant
REACH REACH: Contains No SVHCs
Battery Directive Compliant
Battery Notes Contains Lithium Coin Cell