LUM-IiCR48V-4000 specification sheet

Current Specials & Promotions
Product specification information

Specifications for LUM-IiCR48V-4000

Luminous - Icruze Inverter 4000VA 48V

LUM-IiCR48V-4000 Gallery image 1 [Size: 1148 (W) x 1148 (H)]  
Luminous - Icruze Inverter 4000VA 48V, IiCR48V-4000, Pure Sinewave, Non-Solar, Requires 4x 12V Battery, Batteries not included, Max load of 2850W and a charging current of 21A

Inverters

Luminous

In Stock Buy now!
R 7 470.00 inc VAT
Overview:

Luminous - iCruze Inverter, 4000VA, 48V
The Luminous iCruze 4000VA, 48V inverter offers a max load of 2850W and a charging current of 21A. When purchasing this unit, 4 x 12V Inverlast Tall Tubular batteries, either 150Ah, 200Ah or 220Ah are required for operation. All four batteries must have the same Ah rating and be connected in series. This is not a DIY unit as it has to be connected to your Grid.

Specifications:

©2026 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered.
Specificationsspacer
Product CodeLUM-IiCR48V-4000spacer
Model4KVA
Input Regulated UPS mode
Rated Voltage230V AC
Undervoltage180±5V
Undervoltage Restoration190±5V
Overvoltage260±5V
Overvoltage Restoration250±5V
Input Unregulated ECO mode
Undervoltage140±5V
Undervoltage Restoration150±5V
Overvoltage280±5V
Overvoltage Restoration270±5V
Output
Rated voltage (UPS Mode)230V AC
Voltage (Mains Mode)SAME AS INPUT
Frequency (UPS Mode)50±1Hz
Frequency (Mains Mode)SAME AS INPUT (47-53 Hz)
Load Performance Factor0.6 to 0.8#
Overload> 110%
Transfer Time(typical a.s.)< 10 ms.
Battery
Capacity60Ah-220Ah TUBULAR / FLAT / SMF
Number of Battery4
Typical Recharge Time8-10 hours approx
Battery Boost Volatge55V-57V
ProtectionLOW BATTERY
TDR
TDR Delay4Min approx
Physical
Net weight (Kg.)36.0 Kg
Gross weight (Kg.)38.0 Kg
Dimension (LxWxH)(mm)300x487x 452
Front LCD Displays
Load PercentageDisplays "L085%"
Time to Charge & DischargeDisplay time to charge or discharge in HH:MM
OverloadDisplays "old"
Short CircuitDisplays "sct"
AC MCB TripDisplays "AC:bt"
Front LCD Displays
DC MCB TripDisplays "DC:bt"
No LoadDisplays "nL:dl"
OvertemperatureDisplays "otp"
Battery LowDisplays "Lbt" when batt. completely discharged
Battery High CutDisplays "btHI" When Batt.Voltage Batt.Voltage > 63V
Temp. Sensor FailedDisplays "tSFL" When internal failure
Battery Level SymbolDisplays battery level available
Charging SymbolDisplays when battery is charging
Mains SymbolDisplays spark symbol
Mode SelectionDisplays ECO or UPS Mode
Fault SymbolDisplays if there any fault or trip condition
Alarms
UPS ON/OFF Low Battery5 Beeps of 1Sec. each 1 Beep of 10Sec.
Battery High Cut1 Beep of 10Sec.
NO Load shutdown1 Beep of 10Sec.
Short Circuit Overload shutdown1 Beep of 10Sec. 1 Beep of 10Sec.
Low Battery Warning10 Beeps of 1Sec. each
Mains MCB Trip1 Beep of 10Sec.
Over Temperature1 Beep of 10Sec.
Battery MCB Trip1 Beep of 10Sec.
Temp. Sensor Failed1 Beep of 10Sec.
Environ mental
Operating Temperature0-45°C (32-113°F)
Storage Temperature0-45°C (32-113°F)
Humidity0-95% RH non-condensing